[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 2, Issue 4 (Winter 2009) ::
IJT 2009, 2(4): 287-291 Back to browse issues page
Determination of mercury concentration in the air of dental clinics and the urines of their personnel with cold vapor atomic absorption spectrometry
Hassan Zavvar Mousavi , Ahmad Rouhollahi , Hamid Shirkhanloo
Department of Chemistry, Faculty of Science, K.N Toosi University of Technology,Tehran, Iran , amidshirkhanloo@yahoo.com
Abstract:   (6109 Views)
Background: Dental clinics are known to be one of the largest users of Toxic inorganic mercury. It is well documented that dentists and dental assistants who work with amalgam are chronically exposed to mercury vapor. This study investigates exposure to mercury vapor in a dental clinic.
Methods: GBC cold vapor atomic absorption spectrometry (AAS), using sodium borohydride as the reducing agent, was employed to determine mercury concentrations. The determination of mercury in urine and air was carried out using a flow injection system after sample treatment according to the standard procedure.
Result: In this study mercury exposure in some dentist and dental office personnel was examined. We studied 495 persons (280 dentists and 215 dental personnel) occupationally exposed to mercury while working at 58 dental clinics in Tehran. In addition 305 samples from dental office’s air were taken and their mercury was measured with HG-AAS.
Conclution: In this study, mercury levels in dentists urine and dental office atmosphere were lower than occupational safety and health administration (OSHA). Results acquired from this study show that the amount of mercury were in normal range and it is lower than to the potential for adverse exposure to elemental mercury vapor concentration in a dental office.
Keywords: Air, Dentists, Urine, HG-AAS, Niosh, Toxic of Mercury
Full-Text [PDF 180 kb]   (1888 Downloads)    
Type of Study: Research | Subject: General
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zavvar Mousavi H, Rouhollahi A, Shirkhanloo H. Determination of mercury concentration in the air of dental clinics and the urines of their personnel with cold vapor atomic absorption spectrometry. IJT. 2009; 2 (4) :287-291
URL: http://ijt.arakmu.ac.ir/article-1-66-en.html


Volume 2, Issue 4 (Winter 2009) Back to browse issues page
مجله سم شناسی و مسمومیتهای ایران Iranian Journal of Toxicology
Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 3755